The LAUDA TD tensiometers perform measurements with the Du Noüy ring and Wilhelmy plate according to international standards. Thanks to the powerful load cell with significantly advanced measuring range, it is also possible to determine the densities according to the Archimedes’ principle as well as to measure small weights. The measuring table with sample plate can be moved smoothly without any jerking motions in order to, for example, place the Wilhelmy plate on the sample surface or find the maximum force during ring measurement.

The tensiometers come in a new design and are equipped with some unique technical features. As such, the world‘s smallest thermostat, the LAUDA PTT Peltier thermostating unit can be easily incorporated into the device. Surface and interfacial tensions can be easily measured, precisely and repeatably calculated, displayed, printed, saved and transferred to the computer with a single keystroke.

TD 1 C Ring/Plate tensiometer

Technical features   TD 1 C
Select to compare:  
Mode: Surface/Interfacial tension mN/m Measurement range: 0...300 (ring method); Resolution ±0.1
Mode: Density measurement g/l Measurement range: 0...2,000; Resolution: ±1
Mode: Weight measurement mg Measurement range: 0...5,000; Resolution: ±1
Sample designation Numeric (0...999)
Measurement value storage Results Max. 500, with date and time
Table movement manual Using rotary knob
Maximum detection   Automatic
Ring correction   Automatic according to Zuidema and Waters
Control and evaluation   Command unit (control, display, documented data storage); printer (optional)
Ambient temperature range °C 10...40
Power consumption W 10
Dimensions (WxDxH) mm3 250x120x300
Weight kg ca. 5.0
Cat. No. 100…240 V; 50/60 Hz   LMT 847
   

SUMMARY

TD 3 Ring/Plate tensiometer

Technical features   TD 3
Select to compare:  
Mode: Interfacial tension mN/m Measurement range: 0...300 (ring method); 0...999 (plate method); Resolution: 0.01
Mode: Density determining kg/m3 Measurement range: 0...2,000; Resolution: ±1
Mode: Weight determining mg Measurement range: 0...5,000; Resolution: ±0.1
Temperature range (PTT) °C 5…80 (±0.1)
Magnetic stirrer   Integrated into PTT, adjustable (10 levels)
Table movement mm/s 0.1…1 (10 levels)
Maximum detection   Automatic
Ring correction   Automatic according to Zuidema and Waters
Interface   RS 232, Command remote control
Control and evaluation   Command unit (control, display, documented data storage) PC data transfer (optional); printer (optional)
Ambient temperature range °C 10…40
Power consumption W 10
Dimensions (WxDxH) mm 245x205x335
Weight kg 9.5
Cat. No. 90…240 V 50/60 Hz   LMT 850
   