HCL GAZ ABSORBER ÜNITESI                           GAZ ABSORBER ÜNETISI
                                                                 STANDARD TYPICAL UNITS



 GAS ABSORBER - FALLING FILM TYPE
                                                                 Hcl GAS ABSORBER - ADIABATIC TYPE
 Process Description
                                                                 HCL absorption columns are used for absorption of Hydrochloric gas which
 Efficient gas absorption depends on the following:
                                                                 statutorily are not permitted to vent into the atmosphere, and to produce
 1. Intimate contact  2. Efficient Heat Transfer                 the HCl acid. Hydrogen Chloride is very soluble in water but it's absorption is
 This is achieved in a Falling Film Absorber which is essentially a shell & tube   complicated by the high heat of solution and the high partial pressure over
 heat exchanger in which both, gas to be absorbed and absorbing liquid,   warm  concentrated  solutions.  In  practice,  the  basic  problem  in  making
 flows  co-currently  downward  with  extraction  of  heat  by  circulation  of   concentrated  solutions  is  one  of  efficient  heat  removal.  In  this  type  of
 coolant in the shell. The abssorbing liquid is circulated through a tank till   absorber, the heat of absorption is removed by evaporation of water and
 desired concentration is achieved. The liquid flows at such a rate that the   acid in the column. The vapour being condensed is diluted with 'makeup'
 tubes do not flow full of the liquid but instead, descends by gravity along   therefore, mostly removed via condenser. Concentration and cooling of the
 the inner walls of the tubes as a thin film. Obviously, this produces a much   liquid  phase  is  assisted  by  evaporation  of  water  to  maintain  the
 greater linear velocity for a given rate flow than could be obtained if the   vapour/liquid equilibrium in the lower part of the packed section.
 tube flowed full.                                               The  column  is  constructed  with  a  series  of  packed  sections,  a  gas
 The equipment works as a number of water cooled-wall columns in parallel   introduction point below that, a condenser on the top, and a cooler at the
 and each tube is provided with distribution system on top to effect uniform   bottom and water is sprayed from the top and acid is collected from the
     244
 distribution of both liquid and gas and also formation of a thin liquid film on   bottom. Hcl absorption columns are available in 80DN to 300DN diameter
 the inner surface of the tube.                                  (for the gas rate 10 Kgs/hr to 300 Kgs/hr approx.)


         SANAYİ TIPİ DİSTİLASYON SİSTEMLERİ
                                                                  PACKED
 SALIENT FEATURES                                                 COLUMN          CONDENSER    GAS RATE      CAT. REF.
                                                                                               (Approx.)
                                                                                   HTA (m2)
 1.  High absorption efficiency.
 2.  High acid concentration achievable.                         80mmx3m           0.35m2x2    10Kg/hr       AHCL3
                                                                                   0.5m2x2
                                                                                                             AHCL4
                                                                 100mmx4m
                                                                                               20Kg/hr
 3.  Low outlet temperature.                                     150mmx4m          1.5m2x2     60Kg/hr       AHCL6
 4.  Easy operation and maintenance.   HCL GAS ABSORBER          225mmx4.5m        2.5m2x2     150Kg/hr      AHCL9
 5.  Safe Operation due to low isothermal  temperature.          300mmx4.5m        2.5m2x2     300Kg/hr      AHCL12
 6.  Handle a wide range of gas loading with minimum liquid flow rates
    to maintain full tube wetting.
 7.  All the wetted parts of the falling film absorber  are corrosion
    resistant to all the aggressive  gases  even at elevated temperatures.
 8.  Variation in Hydrogen Chloride Gas flow rates  or Composition
    causes no operation problem.
 Other Area Of Application:
  Hydrogen Chloride Gas / Sulphur Dioxide Gas Absorption
  Hydrogen Chloride Gas / Chlorine Gas Absorption
  Hydrogen Chloride Gas / Chlorine Gas / / Sulphur Dioxide Absorption
  Hydrogen Bromide Gas absorption


 SPECIFICATIONS:


                 NO. OF    MAX. GAS   MAX. ACID
                  TUBE   ABSORPTION   PROD. RATE
 NOMINAL  ABSORBER  TUBE OD  RATE ( Pure HCL) (As 30% HCL )
 SIZE (mm)  AREA (m2)   (mm)   ( kg/Hr)   (kg/Hr)  CAT. REF.
  80      1.00   4/20      30        100      AFFA3
  100     1.76   7/20      60        200      AFFA4
  150     4.80   19/20     150       500      AFFA6
  225     7.80   31/20     250       833      AFFA9
  300     15.30  61/20     500       1667     AFFA12
  400     36.00  143/20    1175      3917     AFFA16
  450     47.00  187/20    1500      5000     AFFA18
  600     84.00  333/20    2700      9000     AFFA24